JUMO Logo
  • SALES

    Technical consulting &
    individual offers

    71 339 32 79
    Offers
    71 339 32 84
    Offers
    71 339 32 92
    Offers
    71 339 32 83
    Offers
    SUPPORT

    Service and engineering

    71 339 32 91
    Service
    • Germany
      • German
      • English
    • Switzerland
      • German
      • English
    • Poland
      • Polish
      • English
    • Netherlands
      • Dutch
      • English
    • Sweden
      • Swedish
      • English
    • Belgium
      • Dutch
      • French
      • German
      • English
    • France
      • French
      • English
    • Austria
      • German
      • English
    • Spain
      • Spanish
      • English
    • Italy
      • Italian
      • English
    • Slovenia
      • English
    • Croatia
      • English
    • Serbia
      • English
    • Bosnia
      • English
    • Hungaria
      • English
    • USA
      • English
    • United Kingdom
      • English
  • 0
  • Search for

    Are you looking for suitable products for a specific application? Start product selection guide

  • Products
    • Product Highlights
    • Temperature
      • Automation
      • Paperless recorders
      • Digital indicators
      • Transmitters
      • Platinum temperature sensors Pt100, Pt1000
      • Controllers
      • Switches
      • Thermocouples
      • Thermostats
      • Monitors & limiters
      • Heat meters
      • RTD temperature probes
      • Dial thermometers
      • Contact dial thermometers
      • Accessories
    • Liquid analysis
      • Automation system
      • Electrodes & Sensors
      • Transmitter & Controllers
      • Accessories
    • Pressure
      • Automation system
      • Digital indicators
      • Transmitters
      • Measuring cells
      • Control
      • Accessories
    • Humidity & CO2
      • Automation system
      • Hygrostats
      • Hygro transducers and hygrothermal transducers
    • Flow
      • Automation system
      • Paperless recorders
      • Digital indicators
      • Measuring devices
      • Controllers
      • Flow sensor
    • Level
      • Automation system
      • Paperless recorders
      • Digital indicators
      • Transmitters
      • Level sensors
      • Level probes
      • Controller
      • Float switches
    • Actuator
      • Semiconductor relay
      • Power control
    • Product selector
    • Product list A-Z
  • Applications
    • All applications at a glance
    • Food and beverage
      • Beer production
      • CIP cleaning
    • Water and wastewater
      • Ground water treatment
      • Swimming pool water treatment
      • Cooling water treatment
    • Railway technology
      • Diesel propulsion
      • Chassis technology
      • Climate control
      • Water supply
    • Hydrogen
    • Aquaculture
    • Industrial furnace construction
      • Continuous heat treatment process
      • Discontinuous heat treatment process
    • Heating and air-conditioning technology
      • Air-conditioning technology
      • Heating technology
      • Heat and cold meters
    • Shipbuilding industry
      • Tank ship
      • Water treatment
      • Heating and cooling systems
    • Greenhouses
  • Services
    • Download center
    • Product archive
    • Frequently asked questions
    • JUMO Engineering
    • Special production
      • Metal technology
    • Commissioning
      • Field service
      • Configuration service
    • Calibration
      • DAkkS calibration
      • Temperature calibration
      • Pressure calibration
      • Humidity calibration
      • On-site calibration
    • Maintenance
      • Spare parts
      • Repair services
      • Returns
      • Technical support
      • Maintenance contracts
    • Trainings
      • Seminars
      • Exclusive trainings
      • Webinars
      • E-Learnings
    • Electronic data exchange
      • BMEcat
      • EPLAN
  • About Us
    • Profile and focus
    • Expertise and strengths
    • Development partnership
    • Success stories
    • Locations worldwide
    • Contact
    • Fair dates
    • Management
    • Management JUMO Poland
    • History
    • Blog
    • Career
      • Internship and practice for students
      • Vacancies
      • Values and culture
      • Contact with HR department
    • Current topics
      • News
      • upcoming-events-pl
      • Software Newsletter
      • Newsletter
      • Customer magazine
      • Company information
    • Imprint
    • General terms and conditions
    • Privacy policy
{}
start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar
Type 202545

JUMO dTRANS Rw 01

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

What is to be taken into account for ultra-pure water measurement?

Measurement and calibration must be carried out in a closed measuring circuit or in a closed container.
Any contact of the medium to be measured with the atmosphere results in a notable change of its conductivity.
For this, we recommend to use a measuring cell with ASTM inspection certificate.

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

An 'ERR' error message appears on the device.

Calibration of the relative cell constant or determination of the temperature coefficient of the medium to be measured was completed with an error. The previous data is saved.
The factory data is displayed (Cell = 100%, ALPH= 2.3).
To remedy the 'ERR' error message, manually change the two parameters using the keyboard (e.g. change by one digit up or down and confirm with the PGM key) or re-calibrate the system.

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

An actual value output is required - What is to be taken into account?

Ensure that the device is equipped with the respective analog output. For this purpose, check the type designation of the device.
Refer to chapter 4.1, Type explanation, in the operating instructions.

0.284

Configuration level C213 - Other outputs I is set.
Actual value output 2 is set in configuration level C214 - Other outputs II.
The scaling is set under the parameters SOL and SOH.
start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

I cannot change settings in the parameter level and the configuration level.

To be able to carry out settings in the two levels, enter the respective CODE for activation first.
Start situation > Measuring mode > Repeatedly press the PGM key until CODE appears. Set the respective CODE by pressing the UP/DOWN keys. Press the PGM key to confirm.
The display returns to 0000. Now, the corresponding level (parameter) can be selected. The code has been entered correctly when the decimal point flashes during entry.

Function Code
Unlock the operator level, CAL and manual activation of Hold. 0110
Unlock the operator and parameter level. 0220
Unlock all levels. 0300

 

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

Is it possible to change the switching behavior of N/C / N/O?

The setting N/O / N/C for the two contacts K1 and K2 can be changed in the configuration level under point C212 (controller outputs).
Both contacts are factory set to NOC.
NOC: (N/O) The corresponding output is active (closed) as long as the switching condition is fulfilled.
NCC: (N/C) The corresponding output is active (closed) as long as the switching condition is not fulfilled.

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

What does Min/Max contact mean?

The configuration level C212 (controller outputs) can be used to change the Min/Max behavior for the two contacts K1 and K2.
MIN contact: The switching condition is fulfilled when the actual value is lower than the set point value.
MAX contact: The switching condition is fulfilled when the actual value exceeds the set point value.

0.111

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

How to check the correct function (actual value display) of the device and the coax cable?

The Redox value can also be preset with a pH simulator as for the pH measurement. Then the Redox value can be read from a table contained in the simulator operating instructions. If the simulator is not available, it is possible to directly supply voltage to the device input (BNC socket) and, to check the coax cable, to the end of the cable.
The Rd value can be read on the device according to the voltage.
The device should have the factory settings and should not display any error messages.

pH value
Voltage
2 pH +295,8 mV
4 pH +177,48 mV
7 pH 0 mV
10 pH -177,48 mV
10 pH -295,8 mV


0.712

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

How to start the calibration process?

To be able to start calibration, activate the controller.
Start situation > Measuring mode > Repeatedly press the PGM key until CODE appears > Enter 0300 and confirm with PGM > Press the Exit key once > Simultaneously press the PGM + Down key.
A temperature of 25.0 appears in the top (red) display, °C appears in the bottom (green) display, the decimal point in the bottom display flashes.

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

JUMO Campus

Discover training opportunities
More

Or send us a message

Contact us and we will answer your questions – whether about basics or specific topics.
Send a message now
CONTACT

JUMO Sp. z o.o.
ul. Bierutowska 57-59
51-317 Wrocław

Phone: 71 339 32 79
Fax: 71 339 32 80
EMail: info.pl@jumo.net

  • Imprint
  • Privacy policy
  • General Terms of Business Relations
QUICKLINKS
  • Temperature sensors
  • Platinum thermometric resistors
  • Pressure transducers
  • Hydrostatic level probes
  • pH electrodes and conductivity meters
FOLLOW US
YouTubeFacebookLinkedInTwitterInstagram
More than Sensors + Automation
Imprint
Privacy policy
General Terms of Business Relations
Complementary Content Deferred Modules
  • ${title}${badge}
${loading}
Deferred Modules